Product Profile:
 |
General Description:
This product is a fast dry, modified alkyd, sandable primer.
|
 |
Common Usage:
Typical uses include structural steel, storage tanks, steel fences, machinery
and equipment, bridges and towers. This coating can also be used as a
barrier coat over alkyds to permit vinyls, epoxies or other coatings containing
strong solvents to be applied.
|
 |
Color: Gray |
 |
Finish: Flat |
Coating Systems:
 |
Finish Coats:
Typical topcoats include alkyds, lacquer, urethanes, or epoxies. Each
service environment may require a specific coating system or combination of
Anchor products. Consult your Anchor representative for specific job
recommendations.
|
Surface Preparation:
 |
For maximum performance, the recommended substrate should be blasted in
accordance with SSPC-SP7. If blast cleaning is not feasible, the substrate
should be degreased in accordance with SSPC-SP1. All burrs should be
removed and sharp edges or rough weld seams should be ground down. Full
use should then be made of mechanical power tools, in conjunction with wire
brushing and chipping to remove all loose rust and mill scale to a standard of
cleanliness conforming to SSPC-SP2 or SP-3.
|
Technical Data:
 |
Volume Solids: 45.06% |
 |
Recommended Thickness: 1.6-2.0 mils dry. |
 |
Drying Time:
| Temperature |
 |
To Touch |
 |
To Recoat |
 |
| 75 F / 55% R.H. |
|
20 Minutes |
|
30 Minutes |
|
| (Cooler temperatures and higher humidity will lengthen drying time) |
|
 |
Architectural and Industrial Maintenance Category: Not Intended For Residential Use; Shop Use Only |
 |
Actual V.O.C.: 3.91 lbs./gal. (469 g/l) |
 |
Theoretical Coverage:
724 sq. ft./ gallon @ 1 mil dry, assuming no application loss. Coverage will
vary depending on surface texture and application technique.
|
 |
Packaging: Tote Tanks, 55 Gallon drums, 5 Gallon pails, and 1 Gallon cans
|
 |
Storage Temperature:
| Minimum 20 F |
 |
Maximum 110 F |
|
 |
Chemical Resistance:
 |
Alkalis: |
 |
Poor |
 |
Acids: |
 |
Good |
 |
Water: |
 |
Very Good |
|
 |
Health & Safety:
Refer to the front of this manual, the product label itself, and your Anchor representative concerning a Material Safety Data Sheet for complete information on this product. |
Application:
 |
Coverage Rates Per Coat:
 |
|
 |
Dry Mils |
 |
Wet Mils |
 |
Sq.Ft./Gal. |
 |
Suggested: |
|
1.8 |
|
4.0 |
|
401 |
 |
Minimum: |
|
1.6 |
|
3.5 |
|
451 |
 |
Maximum: |
|
2.0 |
|
4.4 |
|
361 |
|
 |
Mixing: Stir thoroughly, making sure no pigment remains on the bottom of the can.
|
 |
Thinning: Use Anchor #J-1131 synthetic thinner.
|
 |
Surface Temperature:
| Minimum 40 F |
 |
Maximum 110 F |
| The surface should be dry and the relative humidity should be less than 85%.
|
|
 |
Application Equipment:
 |
Airless Spray
 |
Pressure: |
 |
1200-2200 psi |
 |
Tip: |
 |
.011"-.015" |
|
 |
Conventional Spray
|
 |
 |
Air Pressure: |
 |
60-80 psi |
 |
 |
Fluid Pressure: |
 |
10-20 psi |
|
 |
Cleanup: Use Anchor #J-1131 synthetic thinner. |
 |
Application Considerations:
On a derusted surface the application of a dry film thickness of at least 2 mils is
recommended. With any oxidative coating, faster dry time may be obtained
with increased air movement and/or higher substrate or material temperature.
|
Limited Warranty: The technical data on this label or on other data is true and accurate to the best of our knowledge. We guarantee our products to conform to ANCHOR PAINT MFG. CO. quality control standards. Due to misuse in handling, storage, application and workmanship or variables such as weather or surface integrity that are beyond our control, Anchor Paint does not authorize any representative to make any warranty or merchantability of fitness of this product. Any liability whatsoever of Anchor Paint Mfg. Co. to the buyer or user of this product is limited to the purchaser’s cost of the product itself.
|