Click here to open the
Colorizer web-deck color viewer



 
Low VOC Gray Primer, High Solids
#B-7911
<<Back to Data Sheets

Product Profile:
General Description:
This product is a ready-to-spray, quick drying phenolic alkyd primer.
Common Usage:
Typical substrates include construction equipment, original equipment manufacturing and shop applications.
Color: Gray
Finish: Low Sheen
 
Coating Systems:
Finish Coats:
Typical topcoats include Anchor #3500 series LOVOC enamels or #900 series Saf-T-Gard 2 gloss enamels. Each service environment may require a specific coating system or a combination of Anchor products. Consult your Anchor representative for specific job recommendations.
 
Surface Preparation:
The faster dry the material, the greater the cleaning required. The surface substrate should be cleaned in accordance with SSPC-SP6 commercial blast . If this is not feasible, then clean to SSPC-SP1. All burrs should be removed and sharp edges or rough weld seams ground down. Where weathered steel is evident and where the substrate has reached rust grade, appropriate chemical cleaning or blasting will be necessary.
 
Technical Data:
Volume Solids: 54-56%
Recommended Thickness: 1.6-2.0 mils minimum dry.
Drying Time: 
Temperature To Touch To Recoat
75 F / 55% R.H. 20 Minutes 40 Minutes
(Cooler temperatures and higher humidity will lengthen drying time)
Architectural and Industrial Maintenance Category: Quick Dry Primers
Maximum Allowable V.O.C.: 3.8 lbs./gal. (450 g/l)
Actual V.O.C.: 3.03 lbs./gal. (403 g/l)
Theoretical Coverage:
920 sq.ft./ gallon @ 1 mil dry, assuming no application losses. Coverage will vary depending on surface texture and application technique.
Packaging: 55 Gallon drums, and 5 Gallon pails
Storage Temperature:
Minimum 20 F Maximum 110 F
Chemical Resistance:
Alkalis: Fair
Acids: Good
Water: Good
Health & Safety:
Refer to the front of this manual, the product label itself, and your Anchor representative concerning a Material Safety Data Sheet for complete information on this product.

Application:
Coverage Rates Per Coat: 
Dry Mils Wet Mils Sq.Ft./Gal.
Suggested: 1.8 3.2 510
Minimum: 1.6 2.8 574
Maximum: 2.0 3.5 460
Mixing: Stir thoroughly, making sure no pigment remains on the bottom of the can.
Thinning: This coating is V.O.C. compliant, thin only if necessary with Anchor # J-1131 or #T-50 for spray applications if permitted by federal, state, and local regulations.
Surface Temperature:
Minimum 40 F Maximum 110 F
The surface should be dry and the relative humidity should be less than 85%.
Application Equipment:
Airless Spray
Pressure: 1200-2200 psi
Tip: .011"-.015"
Conventional Spray
Air Pressure: 60-80 psi
Fluid Pressure: 10-20 psi
Cleanup: Use Anchor #J-1131 or #T-50
Application Considerations:
Spray application only. Apply in wet coats to avoid dusting. When spraying, use a cross-hatch method, overlapping each pass 50%. Clean spray equipment thoroughly before and after each use. On a derusted surface the application of a dry film thickness of at least 2.0 mils is recommended. Due to the high solids of this product, care should be taken to not overbuild the coating. Applying too much will lengthen the dry time and possibly result in "mudcracking" in the film.

Limited Warranty:
The technical data on this label or on other data is true and accurate to the best of our knowledge. We guarantee our products to conform to ANCHOR PAINT MFG. CO. quality control standards. Due to misuse in handling, storage, application and workmanship or variables such as weather or surface integrity that are beyond our control, Anchor Paint does not authorize any representative to make any warranty or merchantability of fitness of this product. Any liability whatsoever of Anchor Paint Mfg. Co. to the buyer or user of this product is limited to the purchaser’s cost of the product itself.

 

<<Back to Data Sheets